Informations sur le produit "Male Catheterization and Enema Simulator"
The simulator imitates the special shape of the urethral canal of a male patient. A urinary bladder catheter is inserted according to a suitable technique to reach the bladder. Reaching the bladder causes urine (water) to flow out.

The feel of the penis is closely similar to that of a real human penis. Techniques such as disinfecting of surroundings of the urethral orifice and cleaning of the pubic area can be practiced.

The main body can be separated at median line so that the shape of the urethra, the insertion position of the catheter, and the anatomical positional relationship can be studied.



Features

- The simulator is of actual size allowing the training of catheterization and glycerin enema for an adult male.

- Since soft and stretchable materials are used for the pubic area, the appearance and the feel are realistic when practicing.

- All techniques of catheterization, such as disinfecting of the pubic area, inserting, fixing, and removing the catheter, can be practiced.

- The simulator is shaped to imitate correct manipulation of the penis to allow passage through the urethra.



Inserting the catheter will be difficult if the position of penis is not correct during insertion.

- Techniques, such as pulling back the foreskin, disinfecting and cleaning, can be performed.

- The movability of the penis is also close to that of a real human penis.

- This allows practicing to fix the penis.

- The main body can be separated, and the urethral canal and bladder are transparent. This allows instruction of checking the insertion state of the catheter into the urethral canal and the balloon in the bladder.

- By exchanging the prostate, the urethral stricture due to hypertrophy can be reproduced.

- The attached tool exclusive to a glycerin enema can be inserted through the anus to the rectum. This allows practicing a glycerin enema.



Size: 29 x 53 x 32 cm,
Weight: 2.3kg
Documents
Anleitung / Manual LM109 Herunterladen

0 sur 0 évaluations

Laissez une évaluation !

Partagez avec d'autres clients votre avis sur le produit.


Koken

Koken Co., Ltd.
1-4-14 Koraku, Bunkyo-Ku
112-0004 Tokyo
Japan
narumi.kida@kokenmpc.co.jp

Verantwortlich/Responsible:

Erler-Zimmer Medical GmbH
Hauptstrasse 27
77886 Lauf
Germany
info@erler-zimmer.de


Achtung! Medizinisches Ausbildungsmaterial, kein Spielzeug. Nicht geeignet für Personen unter 14 Jahren.

Attention! Medical training material, not a toy. Not suitable for persons under 14 years of age.


Documents
Anleitung / Manual LM109 Herunterladen

D'autres clients ont également acheté

Tracheostomy management simulator
This model can be used to practice the procedures carried out for tracheostomypatients in the fields of nursing and caregiving when replacing cannulas or performing suction through a cannula. The model can be divided into two halves and the trachea section is transparent, allowing confirmation of the state of cannula insertion and the position of the suction catheter in the cannula during suction. In addition, with the specially provided cannula attached, a ventilator can be operated by connection a test lung (simulated lung) to the model.Features- Allows the user to practice the procedures for replacing cannulas.- As the trachea section is transparent, the state of inflation of the cuff can beobserved, and by using the specially provided cannula, the approximate optimum pressure can be confirmed. (Because the posterior wall of the trachea is soft, the user can feel the compression of the trachea that results when the cuff is overinflated.)- The transparent trachea facilitates explanation of how the suction cathetershould be positioned, and of how to perform suction using the upper part of the cuff. (The above mentioned practicing of suction procedures can be performed using the simulated sputum.)- The soft neck surface skin allows the user to feel the thyroid cartilage throughthe surface skin.- The detachable trachea section facilitates explanation of the areas where granulation tends to develop.- A ventilator can be operated by attaching the specially provided cannula andconnecting a test lung, allowing confirmation of the alarm tone generated whenair leakage occurs.

950,81 €*

Une force d'innovation constante

Responsabilité sociale

Clients fidèles - Orientation

Compréhension de la qualité

Action durable

Certification ISO 9001

Vos derniers produits consultés