Informations sur le produit "Peter PICC Line"
The only available teaching model which allows review of the principles and tools necessary to validate the knowledge and skills needed for Peripherally Inserted Central Catheter (PICC) insertion. Peter PICC is a portable, lightweight, teaching model featuring anatomically correct superior vena cava, subclavian, jugular, median basilic, basilic and cephalic veins. The moveable chin simulates the occlusion of the jugular vein which can prevent the PICC from taking this path. This model enables staff to practice sterile technique in the set-up and insertion of the PICC line. Palpable ribs permit the practice of measuring proper catheter length from the insertion site to the second or third intercostal space and the confirmation of proper placement of the distal tip of the catheter in the viewable superior vena cava. Standard IV catheter placement is also possible in the major veins, which are barely visible through the translucent arm skin. Gain confidence and master the techniques of PICC insertion and then transfer these skills to patients. Peter PICC Line is an upper torso model including, neck, chin, right arm, ribs, muscle tissue, arm skin, body skin, arm vein set, body vein set with viewable superior vena cava, fluid bag with tubing and a durable, soft-sided cloth carrying case with an additional pouch for supplies.

0 sur 0 évaluations

Laissez une évaluation !

Partagez avec d'autres clients votre avis sur le produit.


D'autres clients ont également acheté

Set de veines pour la ponction pour R18802
Body Vein Tubing Set for Peter PICC Line R18802

218,96 €*
Set de veines pour bras de R18802
Arm Vein Tubing Set for Peter PICC Line R18802Median basilic, basilic and cephalic veins

202,30 €*
Côtes de remplacement pour R18802
Rib Replacement for Peter PICC Line R18802

172,55 €*
Ultrasound-Guided PICC Training Simulator
Peripherally Inserted Central Catheter (PICC) is considered to be a safe approach in placing a catheter in the central line and use of ultrasound guidance is recommended to reduce risk to patients. This brand-new simulator is the one and only model which provides training in full procedural skills from the needle insertion, manipulation of the PICC, to placement of the distal tip in the SVC. Both basilic and cephalic veins are prepared for access to set different levels of challenges in cannulation. The ultrasoundable puncture site is replaceable. The movable shoulder allows for training in positioning of the arm to avoid possible malposition of the catheter. Anatomically correct bifurcation of the vein in the upper chest provides realistic resistance of its outer walls and enables simulations of complications such as malposition of the catheter into the jugular, the thoracodorsal or the subclavian vein. The simulator is ideal for hands-on training of residents, specialist nurses and radiographers.It has the following features:- Excellent image quality and visualization of the needle tip for ultrasound guided venous access- Movable shoulder- Provides training in a variety of procedures from needle insertion to catheter tip placement- „Flash-back“ confirmation of successful venous access- Ribs and right clavicle are included to determine length of the catheter as well as providing anatomical understanding of a correct PICC tip location.- Anatomically correct bifurcation of vein- Simulation of malposition of the cannulaSize: 40 x 60 x 15 cm

2 207,45 €*
Peau de remplacement pour bras de R18802
Arm Skin replacement for Peter PICC Line R18802

160,65 €*
Tissu de muscle pour R18802
Muscle Tissue for Peter PICC Line R18802

199,92 €*
Peau de remplacement pour corps de R18802
Body Skin for Peter PICC Line R18802

284,41 €*

Une force d'innovation constante

Responsabilité sociale

Clients fidèles - Orientation

Compréhension de la qualité

Action durable

Certification ISO 9001

Vos derniers produits consultés