Product information "Compressible mammography phantom"
This phantom is made of soft material and allows the breast to be compressed for mammography (maximum 140N). Due to the three-dimensional structure of the simulated mammary gland fibers and tumors, realistic medical images can be taken. It is suitable for evaluation under different scanning conditions and settings.

Suitable for mammography and tomosynthesis - for training and quality assurance

The phantom has simulated targets and sizes 2, 4, 6, 8 and 10mm. These are available in high and low density and are located on three different levels.

The pathology can be changed by rotating the phantom.

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Other customers also bought

Breast Phantom for Mammography and Breast Tomosynthesis
Breast phantom with adipose and glandular tissue. This breast phantom was designed to simulate breast imaging in mammography and breast tomosynthesis. It represents a compressed breast of 4 cm thickness that can be placed under the compression paddle. This phantom provides a realistic simulation of breast imaging. It was developed for testing and optimizing dose and image quality and for training of medical and technical staff. The phantom is manufactured from virtual data* containing adipose and glandular tissue. The models are handmade unique piece, which can differ slightly in size and design. The phantom can be provided as one-piece anthropomorphic phantom or in a sectional design. Dosimeter openings and pathologic features can be included upon request.Size: 15x11x4cm* References Breast Phantom:1. Graff, C.G., "A new open-source multi-modality digital breast phantom," Proc. SPIE 9783, 978309 (2016).2. Ikejimba, L.C., Graff, C.G., Rosenthal, S., Badal, A., Ghammraoui, B., Lo, J.Y. and Glick, S.J., “A novel physical anthropomorphic breast phantom for 2D and 3D x-ray imaging,” Medical Physics 44(2), 407-416 (2017).
Digital Mammographic Phantom NCCE (fall)
This phantom is designed to evaluate CT-AEC performance. Image quality can be evaluated by noise and standard deviation on the phantom section images. The outer shape of the phantom simulates a compressed breast with D cup size. Targets include simulated microcalcifications, nylon fibrils, acrylic disks, an aluminium ring, Teflon disks, a Teflon ruler (slope) and a resolution test chart with 21 steps with different hydroxyapatite content. Steps range from 0 to 400 mg/cm , with 20mg/cm difference each.

€9,540.23*

Continuous innovation

Social responsibility

Active customer orientation

Understanding quality

Sustainable actions

ISO 9001 certification

Your last viewed products