Product information "Head and Neck Phantom “AVM and Lesion” for CT, X-ray and radiation therapy"
This phantom simulates a contrast medium enhanced head in arterial phase (CT angiography). It covers the vertex to the fifth cervical vertebra.
The phantom has 10 low-contrast lesions in the centrum semiovale and the right hemisphere has an arteriovenous malformation.

The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnosis. It is also suited for training purposes.
The phantom provides a detailed and realistic simulation of vascular structures, soft and bone tissue, including small details such as lymph nodes. Air voids are filled with a cellulose-polymer composite of approx. -160 HU.

Diagnostic Features:
• Realistic simulation of head vessels, bone and soft tissues.
• Arteriovenous malformation of the right hemisphere.
• 5 rod-shaped lesions on each side in the centrum semiovale at the periventricular and supraventricular level.
Documents
Factsheet NLP1620 Download

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Erler-Zimmer

Erler-Zimmer Medical GmbH
Hauptstrasse 27
77886 Lauf
Germany
info@erler-zimmer.de


Achtung! Medizinisches Ausbildungsmaterial, kein Spielzeug. Nicht geeignet für Personen unter 14 Jahren.

Attention! Medical training material, not a toy. Not suitable for persons under 14 years of age.


Documents
Factsheet NLP1620 Download

Other customers also bought

Head phantom “AVM” for CT, X-ray and radiation therapy
This phantom simulates a contrast mediumenhanced head in arterial phase (CT angiography). It covers the vertex to the foramen magnum.The right hemisphere has an arteriovenous malformation.The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnosis. It is also suited for training purposes.The phantom provides a detailed and realistic simulation of vascular structures, soft and bone tissue, including small details such as lymph nodes. Air voids are filled with a cellulose-polymer composite of approx. -160 HU.Diagnostic Features:- Realistic simulation of head vessels, bone and soft tissues.- Arteriovenous malformation of the right hemisphere.
Head phantom “Aneurysm” for CT, X-ray and radiation therapy
This phantom simulates a contrast medium enhanced head in arterial phase (CT angiography). It covers the vertex to the foramen magnum.The phantom has three intracranial aneurysms of the middle cerebral artery (MCA), anterior communicating artery (ACoA), and the basilar artery.The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnosis. It is also suited for training purposes.The phantom provides a detailed and realistic simulation of common brain pathologies, soft and bone tissues. Air voids are filled with a cellulose-polymer composite of approx. -160 HU.Diagnostic features - Aneurysms:• Middle cerebral artery (MCA)left side• Anterior communicating artery (ACoA)left side• Basilar arteryleft side
Head CTA Phantom
This phantom is created from real patient data and is manufactured using the latest technology. Bones, vessels and soft tissue are displayed authentically with realistic CT values ??for all tissues at 120 kVp tube voltage in the CT. If the phantom is to be used primarily with other tube voltages (e.g. 100 kVp), the calibration of the CT values ??can be adjusted accordingly if required. The phantom provides realistic tissue contrasts in X-ray imaging. Air spaces are filled by a material with about -80 Hounsfield units.The head phantom provides an extremely realistic simulation of a head and neck CT angiography (with arterial contrast) of a patient with an arteriovenous malformation on the right side. The phantom is delivered true to the original scale and includes the cervical spine up to the base plate of the fifth cervical vertebra.Size: 19 x 23 x 27cm
Head Phantom “AMV and Lesion” for CT, X-ray and radiation therapy
This phantom simulates a contrast medium enhanced head in arterial phase (CT angiography). It covers the vertex to the foramen magnum.The phantom has 10 low-contrast lesions in the centrum semiovale and the right hemisphere has an arteriovenous malformation.The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnosis. It is also suited for training purposes. The phantom provides a detailed and realistic simulation of vascular structures, soft and bone tissue. Air voids are filled with a cellulosepolymer composite of approx. -160 HU.Diagnostic features:• Realistic simulation of head vessels, bone and soft tissues.• Arteriovenous malformation of the right hemisphere.• 5 rod-shaped lesions on each side in the centrum semiovale at the periventricular and supraventricular level.
Abdomen phantom for CT, X-ray and radiation therapy
This phantom is created from real patient data and is manufactured using the latest technology. Bones, vessels and soft tissue are displayed authentically with realistic CT values ??for all tissues at 120 kVp tube voltage in the CT. If the phantom is mainly to be used with other tube voltages (e.g. 100 kVp), the calibration of the CT values ??can be adjusted accordingly if required. The phantom provides realistic tissue contrasts in X-ray imaging. Air spaces are filled by a material with about -80 Hounsfield units. The phantom provides a highly realistic simulation of a contrast medium enhanced abdomen (late arterial phase) of a patient. The phantom covers the abdomen from the tenth thoracic to the fourth lumbar vertebra. The liver and both kidneys are fully included.Size: 27 x 18 x 17cm

Continuous innovation

Social responsibility

Active customer orientation

Understanding quality

Sustainable actions

ISO 9001 certification

Your last viewed products