Product information "Bladder Catheterization Simulator Henri, male"
This model is a perfect training patient for education and is characterized by the use of high quality materials which are very close to real humans in optical and haptic properties but still are strong and durable. The lower body allows the insertion of the male and also the female genital insert, whilst the anatomical position of genital and urethra is kept strictly. The innovative bladder can be placed in different positions to connect it perfectly with the male or the female genital. The shape of the bladder was created to avoid any unrealistic resistance while inserting the catheter and prevent the students to try “palpating” the correct insertion depth. Also a new kind of valve was used, allowing to have no resistance when the catheter enters the bladder. This specific feature distinguishes the trainer in quality from all other trainers with a classic valve. The bladder is transparent to enable the student to see the position and the blocking of the catheter. The bladder is connected to a fluid bag which allows „urine“ flow if catheterization was successful.


The male genital has a replaceable foreskin, which is movable like in a human, to allow training of handling and hygiene procedures. The model has the most realistic urethra of all currently available catheterization trainers in the market. All for zones of the urethra are represented with corresponding anatomical shape and resistance if catheterized. By attaching a strap a narrowing of the prostate due to BPH or prostate cancer and the necessary use of larger or more rigid catheters can be simulated.


Delivered with a soft carrying case.

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Other customers also bought

Catheterization trainer with male genital insert „Henri“ and female genital insert „Florence“
Named after historical figures Henri Dunant and Florence Nightingale, our professional training models realistically simulate and educate on proper transurethral bladder catheterization in both the male and female human. Their namesake represents our appreciation for important milestones in medical innovation and our commitment to setting new standards for patient care education. The pelvic housing is modular, allowing for the use of both male and female genital inserts while strictly maintaining the unique anatomical position of each. The innovative bladder is designed to accommodate these different anatomies and guarantee an uninterrupted urethral path from meatus to bladder neck. Both anatomical inserts are made with high quality materials that closely simulate real human tissues in both appearance and feel while also remaining strong and durable.The shape of the bladder is specially designed to avoid the unrealistic resistance present in existing catheterization trainers. This helps prevent students from trying to “palpate” the back of the bladder as a way to correctly gauge insertion depth. The bladder also utilizes a new innovative type of valve, preventing unnatural resistance when the catheter enters the bladder. The bladder is also transparent, enabling the student the option to see the catheter’s position and depth. This provides excellent training on foley catheters as the user can actually watch the balloon inflate and be seated. The bladder connects easily to a provided fluid bag which provides natural “urine“ flow following successful catheterization.The male genitalia insert includes a replaceable foreskin, with extremely realistic mobility, to allow training of retraction, handling and other hygiene procedures. The model has the most realistic urethra of all currently available catheterization trainers in the market. All four zones of the urethraare represented with corresponding anatomical shape and resistance during catheterization. Also included is a strap which, when attached will simulate narrowing of the prostate due to BPH or prostate cancer. This module is an excellent to teach and show students exactly why the use of larger or more rigid catheter is critical in this situation.The female genitalia insert is designed to require spreading the flexible labia in order to locate the urethral meatus. The female urethral opening is not immediately obvious and is located very close to the open vaginal canal highlighting the potential for unsuccessful catheterization. The urethraprovides a realistic amount of resistance and feels life-like during catheter insertion. This training model is available as combination with both genital inserts or as a male only or female only version. The inserts are also available for individual purchase so that customers can easily upgrade from a unisex model to a dual sex version.Delivered with a soft carrying case.

€2,597.77*
Bladder Catheterization Simulator Florence, female
This model is a perfect training patient for education and is characterized by the use of high quality materials which are very close to real humans in optical and haptic properties but still are strong and durable. The lower body allows the insertion of the female genital insert as well as the male insert, whilst the anatomical position of genital and urethra is kept strictly. The innovative bladder can be placed in different positions to connect it perfectly with the male or the female genital. The shape of the bladder was created to avoid any unrealistic resistance while inserting the catheter and prevent the students to try “palpating” the correct insertion depth. Also a new kind of valve was used, allowing to have no resistance when the catheter enters the bladder. This specific feature distinguishes the trainer in quality from all other trainers with a classic valve. The bladder is transparent to enable the student to see the position and the blocking of the catheter. The bladder is connected to a fluid bag which allows „urine“ flow if catheterization was successful. The female genital is designed to require spreading the flexible labia to find the urethral meatus. The female urethral meatus is not immediately obvious and located very close to open vaginal canal highlighting potentials for unsuccessful catheterization. The urethra provides a realistic touch and feel when inserting a catheter.Delivered with a soft carrying case.

€1,755.25*

Continuous innovation

Social responsibility

Active customer orientation

Understanding quality

Sustainable actions

ISO 9001 certification

Your last viewed products